Abstract

We demonstrate a Ho:YLF regenerative amplifier (RA) overcoming bifurcation instability and consequently achieving high extraction energies of 6.9 mJ at a repetition rate of 1 kHz with pulse-to-pulse fluctuations of 1.1%. Measurements of the output pulse energy, corroborated by numerical simulations, identify an operation point (OP) that allows high-energy pulse extraction at a minimum noise level. Complete suppression of the onset of bifurcation was achieved by gain saturation after each pumping cycle in the Ho:YLF crystal via lowering the repetition rate and cooling the crystal. Even for moderate cooling, a significant temperature dependence of the Ho:YLF RA performance was observed.

© 2015 Optical Society of America

Full Article  |  PDF Article
OSA Recommended Articles
Picosecond 34 mJ pulses at kHz repetition rates from a Ho:YLF amplifier at 2 µm wavelength

Lorenz von Grafenstein, Martin Bock, Dennis Ueberschaer, Uwe Griebner, and Thomas Elsaesser
Opt. Express 23(26) 33142-33149 (2015)

Ho:YLF chirped pulse amplification at kilohertz repetition rates – 4.3  ps pulses at 2  μm with GW peak power

L. von Grafenstein, M. Bock, D. Ueberschaer, U. Griebner, and T. Elsaesser
Opt. Lett. 41(20) 4668-4671 (2016)

Intracavity gain shaping in millijoule-level, high gain Ho:YLF regenerative amplifiers

Krishna Murari, Huseyin Cankaya, Peter Kroetz, Giovanni Cirmi, Peng Li, Axel Ruehl, Ingmar Hartl, and Franz X. Kärtner
Opt. Lett. 41(6) 1114-1117 (2016)

References

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Figures (5)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription

Metrics

You do not have subscription access to this journal. Article level metrics are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access OSA Member Subscription