Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Lightwave Technology
  • Vol. 36,
  • Issue 20,
  • pp. 4960-4966
  • (2018)

Simultaneous Measurement of Displacement and Temperature Based on a Balloon-Shaped Bent SMF Structure Incorporating an LPG

Not Accessible

Your library or personal account may give you access

Abstract

A novel optical fiber sensor based on a balloon-shaped bent single-mode (BSBS) fiber structure incorporating a long-period grating (LPG) for simultaneous measurement of displacement and temperature is described and experimentally demonstrated. The sensor is fabricated by splicing a BSBS fiber structure based on a Mach-Zehnder interferometer (MZI) with a long-period grating (LPG). The interference dip formed by the BSBS fiber structure is sensitive to external displacement and temperature variation, while that formed by an LPG only depends on temperature, displacement, and temperature and, therefore, can be unambiguously and simultaneously measured by this sensor. Experimental results show that this sensor offers a high displacement sensitivity of −306 pm/μm over the displacement range of 0–80 μm and a temperature sensitivity of 42.9 pm/°C over the temperature range of 20–45 °C. Due to its high measurement sensitivities, low cost, and good repeatability, this sensor could be a realistic candidate for applications where displacement and temperature need to be measured simultaneously.

© 2018 IEEE

PDF Article
More Like This
Highly sensitive displacement sensor based on composite interference established within a balloon-shaped bent multimode fiber structure

Ke Tian, Gerald Farrell, Xianfan Wang, Elfed Lewis, and Pengfei Wang
Appl. Opt. 57(32) 9662-9668 (2018)

Simultaneous measurement of displacement and temperature using a balloon-like hybrid fiber sensor

João P. Santos, Jörg Bierlich, Jens Kobelke, and Marta S. Ferreira
Opt. Lett. 47(15) 3708-3711 (2022)

Balloon-like optical fiber sensor for simultaneous displacement and temperature measurement based on an anti-resonance mechanism

Yaxun Zhang, Zhiliang Huang, Yuxin Liu, Wenmi Li, Xiaoyun Tang, Zhihai Liu, Yu Zhang, and Libo Yuan
Opt. Lett. 48(19) 5177-5180 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.