We demonstrate background-free detection schemes in optical-optical double-resonance dual-comb spectroscopy to improve measurement sensitivity. The dual-comb employing modulation spectroscopy and fluorescence detection achieved 4 and 925 times higher SNR than normal dual-comb setup, respectively.